1. Application CLBM1 series moulded case circuit breaker is one of products developed andmanufactured by adopting international advanced technology. It is supplied withrated insulating voltage 550 and 800V and used for circuit of AC 50/60Hz, ratedope

share:

1. Application
CLBM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied with rated insulating voltage 550 and 800V and used for circuit of AC 50/60Hz, rated operating voltage AC 400V (or below), rated operating current up to 1600A for infrequent changing over and starting of the motors.The products conforms to IEC60947-2 standard.

2. Main Technical Specification(table1)

Type

Rated
current (A)

Polenum-ber

Ratedinsui-atingvolt-age(V)

Rated
operat-ingvolt-age(V)

Arcing-
over
distance
(mm)

Ultimate
short
circuit
breaking
capacity
(KA)

Servies
short
circuit
breaking
capacity
(KA)

Operation
perform-
ance

Utiliza-tioncat-egory

Load

Unload

CLBM1-63L

(6),10
16,20
25 ,32
40,50
63

3, 4

500V

400V

0

25

18

1500

8500

A

CLBM1-63M

0

50

35

CLBM1-100L

(10),16
20,25
32,40
50,63
80,100

800V

0(≤50)

35

22

CLBM1-100M

0(≤50)

50

35

CLBM1-100H

0(≤50)

85

50

1000

7000

CLBM1-225L

100,125
160,180
200,225

≤50

35

22

CLBM1-225M

≤50

50

35

CLBM1-225H

≤50

85

50

1000

4000

CLBM1-400L

225,250
315,350
400

≤50

50

35

CLBM1-400M

≤100

65

42

CLBM1-630L

400,500
630

≤100

50

35

CLBM1-630M

≤100

65

42

CLBM1-630H

≤100

100

65

CLBM1-800M

630,700
800

3

≤100

75

50

CLBM1-800H

≤100

100

65

CLBM1-1250M

1000,1250

≤100

100

65

CLBM1-1250H

≤100

125

75

CLBM1-1600M

1600

≤100

150

80



Note: 6A without thermal protection
The N-pole of four-poles breaker is sited at the right side of the product has four types:
Type A: Without current trip-lease on N pole which making all the time, not closing and opening with the other three poles.
Type B: Without current trip-release on N pole which closing and opening with the other poles.
Type C: With current trip-release which closing and opening with the other three poles.
Type D: With current trip-release which making all the time not closing and opening with the other three poles.

3. Protection Characteristic
The thermodynamic release of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) and table 3 (motor protection circuit breaker).



Table2

Rated current of release (A)

Thermodynamic release( ambient temperature ) land +40°C marine +45°C

Operating current of magnetic release (A)

1.05In(cold state) Inoperative time(h)

1.30In(heat state) Operative time(h)

10≤In≤63

≥ 1

< 1

10In±20%

63

≥ 2

< 2

100≤In≤800

≥ 2

< 2

5In±20% 10In±20%



Table3

Rated current

Thermodynamic release ( ambient temperature ) land +40°C marine +45°C

Operating current of magnetic release (A)

of release (A)

1.0In(cold state) non-trip time(h)

1.20In(heat state) trip time (h)

1.50In(heat state) trip time (h)

7.2In(cold state) trip time(h)

10 ≤ In ≤ 225

≥ 2

<2

≤ 4min

4s < Tp ≤ 10s

12In±20%

225 ≤ In ≤ 630

≤ 8min

6s < Tp ≤ 20s



4. Accessories of Circuit breaker
4.1 The external accessories of the breaker
Motor-driven operation device
1) Wiring diagram of type CDM electromagnetic operation device(fitting AM1-63,100,225) seethe following drawing (wiring diagram of the external accessories of the breaker in the dotted frame)




Code description: SB1 SB2 stand for push button.(provided by users themselves) Number "1" "2" "3" stand for number of wiring terminals.
Voltage rating: AC50Hz 230V 400V DC 220V
2) Wiring diagram of type CD motor-driven operation device (fitting AM1-400 630 800) seebelows (wiring diagram of the external accessories of the breaker in the dotted frame)

IMG_257




Code description: SB1 SB2 stand for push button. (provided by users themselves) "X" stands for line connection terminals
Voltage rating: AC50Hz 230V 400V DC 220V



Rotary handle operation device
The mechanism is used in moulded case circuit breaker to operate the draw-out panel. Powerdistribution panel and supply box outside the panel by turning the handle ,and to ensure thedoor of panel would not be openned when the breaker being on. The hand-drive mechanism can be equiped with two types of operation, one is "A" modelsquare handle , the other is "B" model round handle.

IMG_258



4.2 Release pattern and accessories code
IMG_259
SHT: Shunt release; UVR: Under-voltage release;AX: Auxiliary contact; AL: Alarm contact

Release patternand accessories code

Name/Type

AM1-63,
100, 225

AM1-400

AM1-630

AM1-800

200, 300

No accessories

200: magnetic release (only short circuit protection)300: thermal magnetic release(both overload and short circuit protection)

208, 308

Alarm contact

IMG_260

IMG_261

IMG_262

IMG_263

210, 310

Shunt release

IMG_264

IMG_265

IMG_266

IMG_267

220, 320

Auxiliary contact

IMG_268

IMG_269

IMG_270

IMG_271

230, 330

Under-voltage release

IMG_272

IMG_273

IMG_274

IMG_275

240, 340

Shunt release
Auxiliary contact

IMG_276

IMG_277

IMG_278

IMG_279

250, 350

Shunt release
Under-voltage release

IMG_280

IMG_281

IMG_282

IMG_283

260, 360

Two group of auxiliary contact

IMG_284

IMG_285

IMG_286

IMG_287

270,370

Under-voltage release
Auxiliary contact

IMG_288

IMG_289

IMG_290

IMG_291

218, 318

Shunt release
Alarm contact

IMG_292

IMG_293

IMG_294

IMG_295

228, 328

Alarm contact Auxiliary contact

IMG_296

IMG_297

IMG_298

IMG_299

238, 338

Under-voltage releaseAlarm contact

IMG_300

IMG_301

IMG_302

IMG_303

248, 348

Shunt release, Alarm contact,Auxiliary contact

IMG_304

IMG_305

IMG_306

IMG_307

268, 368

Two group of auxiliary contact,Alarm contact

IMG_308

IMG_309

IMG_310

IMG_311

278, 378

Shunt release, Alarm contact, Under-voltage release

IMG_312

IMG_313

IMG_314

IMG_315


According to user's demands, accessories could lead to direct wire outcoming or line wiringterminals could be added(please mark out in case of making order).

Under-voltage release
Wring diagram of the under-voltage module connected externally (the internal accessories inthe dotted frame)Ue: AC50Hz 230V, 400V


IMG_316



When the operation voltage is 35%~70% of the rated voltage, the under-voltage release shouldmake the breaker trip correctly.When the operation voltage is 85%~110% of the rated voltage, the under-voltage release shouldmake the breaker close.In case of the operation voltage less than 35% of the rated voltage, the under-voltage shouldprevent the breaker from closing.Note: Only the under-voltage release should be energized in advanced, the breaker could berecramped and turned-on, otherwise the breaker will be damaged.


Shunt release
Scheme of wiring(the internal accessories in the dotted frame)"K" is the slow motion switch normal-close contact connect the coil in series in the shunt release.It turns-on or turns-off voluntarily as soon as the breaker on or off.

IMG_317



Voltage rating: AC50Hz 230V or 400V, DC 110V 220VThe shunt release should make the breaker trip reliably when the operation voltage is 70%~110%of the rated control voltage.


Alarm contact

The position of the breaker in "off" or "on"

IMG_318

The position of the breaker in "free trip" (alarm)

B11 and B12 switch from "close" to "open", statusof B11 and B14 switch from "open" to "close"

Auxiliary Contact

When the breaker is in"off"

IMG_319

For the breaker with frame current400A and above

IMG_320

For the breaker with frame current225A and below

When the breaker is in"on"

When the breaker is in "off", the contacts switch from "close" to "open".When the breaker is in "off",the contacts switch from "open"to close"

Type

Outline Dimensions(mm)

Front panel connection

W

W1

L

L1

L2

H

H1

H2

H3

H4

C

D

E

F

G

W2

W3

CLBM1-63L

76

50

135

170

117

74

92

7

4

85

28.5

48

22

14

100

75

CLBM1-63M

76

50

135

170

117

82

98.5

28

7

4

85

28.5

48

22

14

100

75

CLBM1-100L

92

60

150

185

132

68

86

24

7

4

88

35.5

50

22

17.5

CLBM1-100M

92

60

150

185

132

86

104

24

7

4

88

35.5

50

22

17.5

122

90

CLBM1-100H

92

60

150

185

132

86

104

24

7

4

88

35.5

50

22

17.5

CLBM1-225L

107

70

165

215

144

86

110

24

5

4

102

31.5

50

22

17

CLBM1-225M

107

70

165

215

144

103

127

24

5

4

102

31.5

50

22

17

142

105

CLBM1-225H

107

70

165

215

144

103

127

24

5

4

102

31.5

50

22

17

CLBM1-400L

150

96

257

357

224

105

155

38

8

6

128

64.5

89

65

φ6

198

144

CLBM1-400M

182

116

270

370

234

110

160

43

8

6

134

70

89

65

φ9

CLBM1-630L

182

116

270

370

234

110

160

43

8

6

134

70

89

65

φ9

240

174

CLBM1-630M

182

116

270

370

234

110

160

43

8

6

134

70

89

65

φ9

CLBM1-630H

210

140

280

380

243

106

145

33

30

128

CLBM1-800M

210

140

280

380

243

106

145

33

30

128

CLBM1-800H

210

140

280

380

243

106

145

33

30

128

CLBM1-1250M

210

140

393

200

CLBM1-1250H

210

140

393

200

CLBM1-1600M

210

140

393

200

Type

Outline Dimensions(mm)

Installation
Dimensions

Back panel connection

Plug-in connection

L4

H5

H6

φD

φD1

L5

L6

H7

H8

H9

H10

J

K

φd1

M

A

B

φd

CLBM1-63L

117

44

66

8

8

25

117

3.5

CLBM1-63M

117

44

66

8

8

25

117

3.5

CLBM1-100L

129

68

108

26

16

92

168

50

62

74

17.5

56

60

6.5

M8

30

129

4.5

CLBM1-100M

129

68

108

26

16

92

168

50

62

74

17.5

56

60

6.5

M8

30

129

4.5

CLBM1-100H

129

68

108

26

16

92

168

50

62

74

17.5

56

60

6.5

M8

30

129

4.5

CLBM1-225L

126

66

110

20

20

94

183

50

69.5

84.5

17.5

54

70

6.5

M8

35

126

5

CLBM1-225M

126

66

110

20

20

94

183

50

69.5

84.5

17.5

54

70

6.5

M8

35

126

5

CLBM1-225H

126

66

110

20

20

94

183

50

69.5

84.5

17.5

54

70

6.5

M8

35

126

5

CLBM1-400L

194

60

120

33

33

169

279

60

83.5

106.5

21

129

60

8.5

M10

44

194

7

CLBM1-400M

200

65

125

36

36

169

299

60

92

110

21

123

100

8.5

M12

58

200

7

CLBM1-630L

200

65

125

36

36

169

299

60

92

110

21

123

100

8.5

M12

58

200

7

CLBM1-630M

200

65

125

36

36

169

299

60

92

110

21

123

100

8.5

M12

58

200

7

CLBM1-630H

128

70

243

7.2

CLBM1-800M

128

70

243

7.2

CLBM1-800H

128

70

243

7.2

CLBM1-1250M

CLBM1-1250H

CLBM1-1600M

le> AM1-1250H 210 140 393 200 AM1-1600M 210 140 393 200

Type

Outline Dimensions(mm)

Installation
Dimensions

Back panel connection

Plug-in connection

L4

H5

H6

φD

φD1

L5

L6

H7

H8

H9

H10

J

K

φd1

M

A

B

φd

CLBM1-63L

117

44

66

8

8

25

117

3.5

CLBM1-63M

117

44

66

8

8

25

117

3.5

CLBM1-100L

129

68

108

26

16

92

168

50

62

74

17.5

56

60

6.5

M8

30

129

4.5

CLBM1-100M

129

68

108

26

16

92

168

50

62

74

17.5

56

60

6.5

M8

30

129

4.5

CLBM1-100H

129

68

108

26

16

92

168

50

62

74

17.5

56

60

6.5

M8

30

129

4.5

CLBM1-225L

126

66

110

20

20

94

183

50

69.5

84.5

17.5

54

70

6.5

M8

35

126

5

CLBM1-225M

126

66

110

20

20

94

183

50

69.5

84.5

17.5

54

70

6.5

M8

35

126

5

CLBM1-225H

126

66

110

20

20

94

183

50

69.5

84.5

17.5

54

70

6.5

M8

35

126

5

CLBM1-400L

194

60

120

33

33

169

279

60

83.5

106.5

21

129

60

8.5

M10

44

194

7

CLBM1-400M

200

65

125

36

36

169

299

60

92

110

21

123

100

8.5

M12

58

200

7

CLBM1-630L

200

65

125

36

36

169

299

60

92

110

21

123

100

8.5

M12

58

200

7

CLBM1-630M

200

65

125

36

36

169

299

60

92

110

21

123

100

8.5

M12

58

200

7

CLBM1-630H

128

70

243

7.2

CLBM1-800M

128

70

243

7.2

CLBM1-800H

128

70

243

7.2

CLBM1-1250M

CLBM1-1250H

CLBM1-1600M


IMG_321